TMB2105N_SVG1
1
1. Switch Actuator
Figure 26
Door Strike
The door strike must be adjusted to have sufficient tension to
hold loading door closed against force of the load tumbling
against it. There is proper adjustment of pull force when 8 to 15
pounds [35.6 N – 66.7 N] is required to open door.
If adjustment is required, refer to Figure 27 and proceed as fol-
lows:
1. To adjust, open door, loosen acorn nut, and turn door strike
screw in or out as required.
2. Retighten acorn nut.
TMB997N_SVG
2
1
1. Door Strike Screw
2. Acorn Nut
Figure 27
Manual Resettable Thermostat
NOTE: The manual resettable thermostat is located as
follows: 030-035-055 - inside access panel on rear of
machine near blower motor. T30-T45 - on blower hous-
ing top surface behind rear guard.
If thermostat trips, contact a qualified service technician.