6.3 Menu Visualisa.
Visualisa.
Last Meas.
Totalizers
Memory
If the values are preceded by this display ‘-------‘; it means they are no longer
guaranteed.
6.3.1 Sub-menu Last Meas.
This menu displays the information of the last measurement. Information displayed
depend on the configuration of the FLEXICOMPT AUTONOME+.
Last meas.
Average flow: xxx [Ech_Deb]
Volume: xxx [Ech_Vol]
Lo.flow vol.: xxx [Ech_Vol]
Nb.of pulses: xxxxx Pulses
Mean temper.: +xx.x °C
Volume
: Measured volume
Average flow
: Average flow of the measurement
Mean temper
: Mean temperature of the measurement
Lo.flow vol
: Volume measured under minimal flow rate during measurement
Nb.of pulses
: Number of pulses of the meter
6.3.2 Sous-menu Totalizers
Totalizers
Vb+: xxxxxx [Ech_Vol]
Vm+: xxxxxx [Ech_Vol]
Vm+
: Totalizer of volume in metering conditions
Vb+
: Totalizer of volume converted to base conditions if the temperature option is
activated
6.3.3 Sub-menu Memory
Enter or validate the date and the measurement number to access the relevant data.
Reference
Memory
Record xxx/hh.mm
Year/Month
Day
Available information depend on the configuration of the FLEXICOMPT
AUTONOME+. Temperature, converted volume, and mass are displayed if the
temperature option is activated. The measured gas volume is displayed for
information only, it has no metrological value.