FLEXICOMPT AUTONOME+
Page 17/42
This document is available on www.alma-alma.fr
6.4.4 Sub-menu Maintenance
Maintenance
Circuit inf.
Soft.inf.
Periph.inf.
Reg. V and I: x.xxV xxmA
Bat.voltage: x.xxV xx%
PCB temp.L/H: xx°C xx°C
Bat.temp.-/+: xx°C xx°C
Custom soft.: 449 Vxx.xx.xx
Bootloader : 448 Vxx.xx.xx
Custom CRC32: xxxxxxxxxx
Data base: aaaammjjhhmm
WiFi/BLE: Vxx.xx.xx
GPS: Vxx.xx.xx
Sensors
Gas detect.1: Icc = xxmA ; State Wet/Gas
Gas detect.2: Icc = xxmA ; State Wet/Gas
Temperature : +xx.x °C
Reboot
Sensors
:
Gas detect.1
:Current and status (wet or dry) of the gas detector 1
Gas detect.2
:Current and status (wet or dry) of the gas detector 2
Temperature
: Product temperature
Circuit inf.
:
Bat.voltage
: Batteries voltage and remaining charge (from 0% to 100%)
Reg. V and I
: Internal supply voltage of the UNI-2 circuit
Bat. temp.-/+
: Minimum and maximum values of the batteries temperature
PCB temp.L/H
: Minimum and maximum values of printed circuit operating
temperatures in °C
Soft. inf.
: Information about the software, the database and the app
Periph.inf.
: Information about peripherals (Wi-Fi/Bluetooth and GPS)
Reboot
: When blocked, the UNI-2 reboots. Metrological and supervisor parameters
are saved as well as the measurements recording
6.4.5 Sub-menu Language
Select the display language. This menu is available if a translation catalogue is
uploaded in the UNI-2.