FORM DOC 011 A
MU 7033 EN M
FLEXICOMPT AUTONOME+
Page 25/42
This document is available on www.alma-alma.fr
Flowrate
Coefficients
Main correction curve
Second correction curve for
products with density < 750Kg/m
3
CoEFF_1
CoEFF_2
Flow
1
Flow
2
Min.
flowrate
Max
flowrate
Kv 1
Kv 2
Coefficients applied in accordance with flowrate and product density
7.3.2 Sub-menu Flowrates
Flowrates
Minimum
Maximum
0008.0 [Ech_Deb]
0080.0 [Ech_Deb]
Minimum
:Minimum flowrate of the FLEXICOMPT AUTONOME+. Unit depends on
the configuration (
Config.>Scales>Flowrates
)
Maximum
: Maximum flowrate of the FLEXICOMPT AUTONOME+. Unit depends on
the configuration (
Config.>Scales>Flowrates
)
7.3.3 Sub-menu Volumes
Volumes
Fixed quant.
00000 [Ech_Vol]
Minimum
00200 [Ech_Deb]
Delay
00000 [Ech_Deb]
Class
0.5
Minimum
: Minimum measured quantity to guaranty the measurement. Unit depends
on the choice made for the scale interval
Fixed quant.
: End of counting fixed volume of the FLEXICOMPT AUTONOME+. Unit
depends on the choice made for the scale interval. Not applicable without gas
detectors
Delay
: Delay for the additional volume (upper gas detector dry). Unit depends on the
choice made for the scale interval. Not applicable without gas detectors
Class
: Accuracy class of the FLEXICOMPT AUTONOME+: 0.5