EasyManua.ls Logo

Alma FLEXICOMPT AUTONOME+ - Sub-Menu Flowrates; Sub-Menu Volumes

Alma FLEXICOMPT AUTONOME+
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FORM DOC 011 A
MU 7033 EN M
FLEXICOMPT AUTONOME+
Page 25/42
This document is available on www.alma-alma.fr
Flowrate
Coefficients
Main correction curve
Second correction curve for
products with density < 750Kg/m
3
CoEFF_1
CoEFF_2
Flow
1
Flow
2
Min.
flowrate
Max
flowrate
Kv 1
Kv 2
Coefficients applied in accordance with flowrate and product density
7.3.2 Sub-menu Flowrates
Flowrates
Minimum
Maximum
0008.0 [Ech_Deb]
0080.0 [Ech_Deb]
Minimum
:Minimum flowrate of the FLEXICOMPT AUTONOME+. Unit depends on
the configuration (
Config.>Scales>Flowrates
)
Maximum
: Maximum flowrate of the FLEXICOMPT AUTONOME+. Unit depends on
the configuration (
Config.>Scales>Flowrates
)
7.3.3 Sub-menu Volumes
Volumes
Fixed quant.
00000 [Ech_Vol]
Minimum
00200 [Ech_Deb]
Delay
00000 [Ech_Deb]
Class
0.5
Minimum
: Minimum measured quantity to guaranty the measurement. Unit depends
on the choice made for the scale interval
Fixed quant.
: End of counting fixed volume of the FLEXICOMPT AUTONOME+. Unit
depends on the choice made for the scale interval. Not applicable without gas
detectors
Delay
: Delay for the additional volume (upper gas detector dry). Unit depends on the
choice made for the scale interval. Not applicable without gas detectors
Class
: Accuracy class of the FLEXICOMPT AUTONOME+: 0.5

Table of Contents

Other manuals for Alma FLEXICOMPT AUTONOME+