7.3.6 Sub-menu Sensors
Sensors
OFF
ON
ON
: Before validation, make sure both gas sensors are dry and well-connected to
the FLEXICOMPT AUTONOME+.
7.3.7 Sub-menu Rcs thres.
Detection thresholds of metering inputs at zero flow and at maximal flow.
Rcs thres.
RCS minimum
RCS maximum
005 %
050 %
7.3.8 Sub-menu Auto save
Set the time required at the end of measurement before automatic recording of the
measurement data (in seconds).
Auto save
000 s
Auto save=0: Data recording is manual, it is done by pressing RESET. It causes
the volume reset.
Auto save>1: Data recording is automatic, it is done when the time-out is up. The
RESET key is disabled. The volumes counted during the time-out are added at
recording of the measurement data.
For example, the parameter can have the value that follows:
Auto save=060. Automatic recording with time-out 60 seconds
7.3.9 Sub-menu MPLS
Do not enable this feature.
Enable
MPLS
OFF
ON
Enable
: Choose
OFF