8.1.2 Modification of the setting parameters
The configuration parameters can only be modified by pressing the micro BP Metro
on the electronic board.
Only approved persons are permitted to change parameters.
Any other operation must be done by approved person as it could affect the
metrological nature of the FLEXICOMPT AUTONOME+.
8.2 Hydraulic sleeve
The downstream and upstream sleeves allow the setting of suitable fittings (4” coupler,
½ snap coupling, etc.).
These sleeves are fastened with 4 screws on the turbine meter and can be removed to
check the status of the turbine.
Any other operation must be done by approved person as it could affect the
metrological nature of the FLEXICOMPT AUTONOME+.
Position the upstream coupling so that in use the downstream coupling is
in the lowest position than the upstream coupling
Position the upstream coupling as laid down the drawing and the pictures
below
Ensure a good sealing
Check that the straining sieve and honeycombs are clean (at the
entrance of the turbine and after the sieve)
To ensure electrical continuity, the upstream and downstream couplings
of the FLEXICOMPT AUTONOME+ must be sealed with conductor such
as Loctite 577.
Positioning upstream bent sleeve