Unplug the 6 wires of the 2DLA01-spacer from the terminal block B2 (see Picture
A)
Picture A
8.3.3 Removing the 2DLA01-spacer from the turbine
Remove the 2DLA01-spacer (15) from the turbine body
Keep by your side the ring (37) and the washer (38) of the 2DLA01-spacer cable
8.3.4 Setting of the new 2DLA01-spacer
Grease the rings (39) of the turbine body and the 2DLA01-spacer (translucent
grease for food contact)
Put back the washer (38) and the ring (37) on the cable of the new 2DLA01-
spacer
Pass the 6 wires and then the cable through the wires pass through of the turbine
body
15
37
38
Terminal block B2