Installation
MN-39404 • Rev 0 • 05/18 • AR-7T Series Electric Rotisserie Manual 19
General Installation Requirements
In order to maintain established National Sanitation
Foundation (NSF) standards, all counter- mounted
appliances must be sealed to the counter with a RTV
Silicone (room temperature vulcanization silicone) or
silastic meeting NSF requirements.
The oven must be installed in a well ventilated room
obeying the local ventilation codes and standards and on a
non-combustible, level surface.
Do not install this oven in any area where it may be
aected by any adverse conditions such as steam, grease,
dripping water, high temperatures, or other severely
adverse conditions.
The oven must be installed in a location to provide easy
access to the controls. The oven is to be positioned at
a safe and convenient height in order to provide easy
loading and unloading of hot products.
This oven must be kept free and clear of any obstructions
blocking access for maintenance or service.
Leveling
Level the oven by
adusting the feet.
Inspect the level periodically to ensure that the oor
has not shied or the oven has moved.
Failure to properly level this oven can cause improper
function.
WARNING
To prevent personal injury, death or
property damage:
Do not store or use gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.