26 MN-39404 • Rev 0 • 05/18 • AR-7T Series Electric Rotisserie Manual
Grease Collection
How to Change Grease Collection Container(s)
NOTE: Empty the full grease collection container every
eight grease collection cycles.
1. Set the valve handle (1) to the CLOSED position.
2. Place an empty grease collection container near the
fullcontainer.
3. Loosen the radial nut on the grease collection
hose (2) and disconnect the hose and ttings from
the full container. Hang the hose on the hose hanger
bracket (3), if supplied.
4. Remove the caps from both grease collection
containers. Switch the caps to the other container;
place the cap with the union tting on the empty
container, and the cap without the union tting on the
full container. Turn both caps until tight (4).
5. Remove the grease collection hose from the hose
hanger bracket. Attach the hose to the radial nut on the
empty container (5). Turn the radial nut until tight.
6. Set the valve handle (1) to the OPENposition.
7. Properly dispose of the grease in the full container.
WARNING
To prevent serious injury and property
damage from slippery oor conditions,
make sure that the grease valve is closed,
and the grease collection hose is hung on
the hose holder bracket when changing the
grease collection containers.
CLOSED
OPEN
1
3
4
2
5

Table of Contents