APPENDIX D: COMMUNICATION CODES
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908 D-13
Control Originated Response Command Set
These are commands returned by the Control, via the RS-485/RS-232 port.
NAME COMMAND DATA SIZE
COUNTER “CR” Read ReflowCntrs.dwTotalUsageCnt (Total Usage Cntr: 0000000 – 9999999) 7 Bytes
, 1 Byte
ReflowCntrs.dwGoodReflowCnt (Good Rflo Cntr: 0000000 – 9999999) 7 Bytes
, 1 Byte
Sign (Clean Counter plus or minus sign: + or -) 1 Byte
ReflowCntrs.stClean.sdCnt (Clean Counter: 000000 – 999999) 6 Bytes
, 1 Byte
Sign (Replace Counter plus or minus sign: + or -) 1 Byte
ReflowCntrs.stReplace.sdCnt (Replace counter: 000000 – 999999) 6 Bytes
, 1 Byte
ReflowCntrs.stClean.fStatus (Clean counter status: 0 = OFF, 1 = ON) 1 Byte
, 1 Byte
ReflowCntrs.stReplace.fStatus (Replace counter status: 0 = OFF, 1 = ON) 1 Byte
, 1 Byte
ReflowCntrs.stClean.enAction (Clean counter action: 0 – 1) 1 Byte
0 = STOP
1 = CONTINUE
, 1 Byte
ReflowCntrs.stReplace.enAction (Replace counter action: 0 – 1) 1 Byte
0 = STOP
1 = CONTINUE
39 Bytes Total
LOAD “LR” Read Returns the current active profile (01 – 63) 2 Bytes
MONITOR “MR” Read DispProfile.ProfileNum (Active screen number 000 – 255) 3 Bytes
0 NO_SCRN_DEF = 0,
1 ALLPIXELSON,
2 ALLPIXELSOFF,
3 BAUDSCR,
4 BUZZER,
5 CLEAN_CNTR,
6 CLEAN_CNTR_SETUP,
7 COARSE_HEATING,
8 COMMID,
9 COMMSCR,
10 COPYSCR,
11 COPYSCR2,
12 COPYRIGHT
13 DATASCR,
14 DEFAULTS,
15 FINE_HEATING,
16 FREQ_DETECT,
17 GOOD_REFLOW_CNTR,
18 GRAPHSCR,
19 HARDWARE,
20 UNUSED_SCREENID1,
21 HEATSWTEST,