CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
3-22 990-908
BUZZER LOUDNESS
Press the 6 key to bring up the BUZZER
LOUDNESS
adjustment screen. With this
screen, you may adjust the loudness of
the end of cycle buzzer so that it may be
heard reliably against background noise.
<BUZZER LOUDNESS >
BUZZER LOUDNESS : 50 %
0 10 20 30 40 50 60 70 80 90
◄► Adjust ,
▲
Page, Graph / Data
END OF CYCLE BUZZER
Press the 7 key to toggle between OFF and ON for the end of cycle buzzer. When you select the ON
option, a buzzer will sound when the actual thermode temperature reaches the Cool 1 temperature setting
if there is no Postheat stage. If there is a Postheat stage, the buzzer will sound at the Cool 2 temperature
setting.
SET OUTPUT RELAYS
Press the 8 key to bring up the RELAY
screen. The RELAY screen allows you to
select the Alarm for Status actuation
states or each relay.
< RELAY >
1. RELAY 1 : OPEN WHEN NOT ACTIVE
2. RELAY 2 : OPEN WHEN NOT ACTIVE
3. RELAY 3 : OPEN WHEN NOT ACTIVE
4. RELAY 4 : OPEN WHEN NOT ACTIVE
5. RELAY 5 : OPEN WHEN NOT ACTIVE
6. RELAY 6 : OPEN WHEN NOT ACTIVE
7. RELAY 7 : OPEN WHEN NOT ACTIVE
Number Select, Page, Graph / Data
See Appendix B, Electrical and Data Connections for the relay contact pin assignments at Control Status
Connector
J6A.
Press the 1 through 7 keys to bring up the
desired relay screen. For example, press
1 to bring up the RELAY 1 screen.
Press the
1 key to toggle SET RELAY to
between CLOSED and OPEN.
< RELAY 1 >
1. SET RELAY TO : CLOSED
2. WHEN : NOT ACTIVE
Number Select, Page, Graph / Data