CHAPTER 1: DESCRIPTION
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908 1-9
SETUP Key
This key brings up the SETUP MENU screen.
The SETUP MENU screen provides a menu of
operating characteristics for the Control.
< SETUP MENU >
1. HARDWARE SETUP
2. COMMUNICATIONS
3. REFLOW SETUP
4. SYSTEM SECURITY
5. COPY PROFILE
6. SET TO DEFAULTS
7. LANGUAGE
8. I/O STATUS
Number Select an item, Graph / Data
HEAT / NO HEAT Switch
When this switch is in the
HEAT
position, the programmed profile can
initiate heating energy.
When you set the switch to the
NO HEAT
position, no heating current
can flow. This function is required to adjust a new thermode to the
work pieces prior to initiating a heating cycle.