How do I reset the REPLACE THERMODE counter on the Amada Controller?
- PpiercecharlesSep 23, 2025
To clear the 'REPLACE THERMODE' message on the Amada Controller, reset the Replace Thermode Counter.
How do I reset the REPLACE THERMODE counter on the Amada Controller?
To clear the 'REPLACE THERMODE' message on the Amada Controller, reset the Replace Thermode Counter.
What to do if the 'EMERGENCY STOP ACTIVATED' message appears on my Amada Controller?
If the Amada Controller displays 'EMERGENCY STOP ACTIVATED', connect a normally closed relay or switch between pin 1 and pin 2 on the control rear panel connector, EMO. Note: Using a jumper wire in place of a relay or switch will work, but will not meet CE safety requirements. The operator must also clear the condition causing the emergency stop before reflowing can continue.
How to fix OVER POWER ALARM on Amada Controller?
If the Amada Controller displays an OVER POWER ALARM, ensure that the thermocouple is plugged in, undamaged, and still bonded to the thermode. Also, verify the thermocouple polarity. Then, recycle the power on the control.
What does OVER_PWR ALARM mean on Amada Controller and how to fix it?
If the Amada Controller displays an OVER_PWR ALARM, ensure that the thermocouple is plugged in, undamaged, and still bonded to the thermode. Also, check the thermocouple polarity. Then, recycle the power on the control.
How to troubleshoot REFLOW ALARM on Amada Controller?
If you receive a REFLOW ALARM on the Amada Controller, try the following: 1. Set the Course Heating Rate one setting faster. 2. Increase the LOW LIMIT value. 3. Increase the Preheat Time. 4. Check cables between the Control output and the Reflow Soldering Head for loose connections. 5. Check connection between the thermode and thermode holder for loose connections. 6. Increase the diameter of the cables between the Control output and the Reflow Soldering Head.
What to do if I see 'ILLEGAL SECURITY CODE ENTERED' on Amada Controller?
If the Amada Controller displays 'ILLEGAL SECURITY CODE ENTERED', re-enter a new security code.
What causes 'REFLOW BELOW COOL TEMP SETTING' on Amada Controller and how to fix it?
If the Amada Controller displays 'REFLOW BELOW COOL TEMP SETTING', re-enter a Reflow value that is greater than the Cool1 temperature.
What does 'ACCESS DENIED! REMOTE PROFILE SELECTED' mean on Amada Controller?
If the Amada Controller displays 'ACCESS DENIED! REMOTE PROFILE SELECTED', you can ignore the message, or remove the remote profile selection before changing profile numbers at the panel.
How to fix 'ABORT REFLOW: Firing Switch Open' on Amada Controller?
To resolve the 'ABORT REFLOW: Firing Switch Open' error on the Amada Controller, maintain firing switch closure for the required time. It is also recommended to set the FOOTSWITCH RESPONSE MODE to LATCHED after the application has been set up.
How do I fix 'BASEHEAT EXCEEDS PREHEAT TEMP SETTING' on my Amada Controller?
If the Amada Controller displays 'BASEHEAT EXCEEDS PREHEAT TEMP SETTING', re-enter a Baseheat value that is less than the Preheat temperature value.
| Brand | Amada |
|---|---|
| Model | UNIFLOW 4 REMOTE |
| Category | Controller |
| Language | English |
Identifies and explains the functions of the front panel controls and indicators.
Details key controls like Display, Keypad, and Switches.
Covers site preparation, space, and utility requirements for installation.
Explains how to connect external devices and components to the control unit.
Configuration of temperature and time limits, and envelope settings.
Adjusting heating rate and PID settings for optimal temperature control.
Accessing and configuring Hardware, Communications, Reflow, Security, and other settings.
Prerequisites, general safety, and preparation before operating the control.
Details graphical representation of temperature profiles and limits.
Explains the numerical display of process data and abbreviations.
How to use pre-defined profiles or manually input parameters.
Safety precautions and warnings before performing maintenance.
Diagnosing and resolving issues based on alarm messages.
Procedures for thermode cleaning, replacement, and contacting repair service.
Wiring for emergency stop and manual alarm reset functions.