PULSED HEAT CONTROL
UNIFLOW 4 /
UNIFLOW 4 REMOTE
OPERATION MANUAL

Table of Contents

Questions and Answers

  • S
    Steven ValdezSep 23, 2025
    How do I reset the REPLACE THERMODE counter on the Amada Controller?
    • P
      piercecharlesSep 23, 2025
      To clear the 'REPLACE THERMODE' message on the Amada Controller, reset the Replace Thermode Counter.
  • K
    Kathy Brown DDSAug 25, 2025
    What to do if the 'EMERGENCY STOP ACTIVATED' message appears on my Amada Controller?
    • K
      Kenneth JohnsonAug 25, 2025
      If the Amada Controller displays 'EMERGENCY STOP ACTIVATED', connect a normally closed relay or switch between pin 1 and pin 2 on the control rear panel connector, EMO. Note: Using a jumper wire in place of a relay or switch will work, but will not meet CE safety requirements. The operator must also clear the condition causing the emergency stop before reflowing can continue.
  • C
    Cristina KingAug 25, 2025
    How to fix OVER POWER ALARM on Amada Controller?
    • R
      Ronald DanielsAug 26, 2025
      If the Amada Controller displays an OVER POWER ALARM, ensure that the thermocouple is plugged in, undamaged, and still bonded to the thermode. Also, verify the thermocouple polarity. Then, recycle the power on the control.
  • A
    ariasjillianAug 26, 2025
    What does OVER_PWR ALARM mean on Amada Controller and how to fix it?
    • C
      Cassandra BurchAug 27, 2025
      If the Amada Controller displays an OVER_PWR ALARM, ensure that the thermocouple is plugged in, undamaged, and still bonded to the thermode. Also, check the thermocouple polarity. Then, recycle the power on the control.
  • T
    Teresa YoungAug 27, 2025
    How to troubleshoot REFLOW ALARM on Amada Controller?
    • B
      Brian ClarkAug 27, 2025
      If you receive a REFLOW ALARM on the Amada Controller, try the following: 1. Set the Course Heating Rate one setting faster. 2. Increase the LOW LIMIT value. 3. Increase the Preheat Time. 4. Check cables between the Control output and the Reflow Soldering Head for loose connections. 5. Check connection between the thermode and thermode holder for loose connections. 6. Increase the diameter of the cables between the Control output and the Reflow Soldering Head.
  • M
    Margaret EstradaSep 14, 2025
    What to do if I see 'ILLEGAL SECURITY CODE ENTERED' on Amada Controller?
    • D
      dawn24Sep 14, 2025
      If the Amada Controller displays 'ILLEGAL SECURITY CODE ENTERED', re-enter a new security code.
  • W
    wbrownSep 12, 2025
    What causes 'REFLOW BELOW COOL TEMP SETTING' on Amada Controller and how to fix it?
    • C
      cassandra96Sep 12, 2025
      If the Amada Controller displays 'REFLOW BELOW COOL TEMP SETTING', re-enter a Reflow value that is greater than the Cool1 temperature.
  • D
    Donna MartinSep 13, 2025
    What does 'ACCESS DENIED! REMOTE PROFILE SELECTED' mean on Amada Controller?
    • X
      xsimmonsSep 13, 2025
      If the Amada Controller displays 'ACCESS DENIED! REMOTE PROFILE SELECTED', you can ignore the message, or remove the remote profile selection before changing profile numbers at the panel.
  • T
    Tonya ThompsonSep 4, 2025
    How to fix 'ABORT REFLOW: Firing Switch Open' on Amada Controller?
    • J
      Joseph SpencerSep 4, 2025
      To resolve the 'ABORT REFLOW: Firing Switch Open' error on the Amada Controller, maintain firing switch closure for the required time. It is also recommended to set the FOOTSWITCH RESPONSE MODE to LATCHED after the application has been set up.
  • C
    Charlene BrennanSep 2, 2025
    How do I fix 'BASEHEAT EXCEEDS PREHEAT TEMP SETTING' on my Amada Controller?
    • P
      Pamela PhillipsSep 2, 2025
      If the Amada Controller displays 'BASEHEAT EXCEEDS PREHEAT TEMP SETTING', re-enter a Baseheat value that is less than the Preheat temperature value.

Summary

Chapter 1: Description

Section III: Controls and Indicators

Identifies and explains the functions of the front panel controls and indicators.

Front Panel Controls Overview

Details key controls like Display, Keypad, and Switches.

Chapter 2: Installation and Setup

Section I: Planning for Installation

Covers site preparation, space, and utility requirements for installation.

Section II: Connections To External Equipment

Explains how to connect external devices and components to the control unit.

Chapter 3: Using Programming Functions

Schedule Setup Parameters

Configuration of temperature and time limits, and envelope settings.

Heating Rate and PID Control

Adjusting heating rate and PID settings for optimal temperature control.

System Setup Menus

Accessing and configuring Hardware, Communications, Reflow, Security, and other settings.

Chapter 4: Operating Instructions

Before You Start and Safety

Prerequisites, general safety, and preparation before operating the control.

Graph Screen Interpretation

Details graphical representation of temperature profiles and limits.

Data Screen Interpretation

Explains the numerical display of process data and abbreviations.

Operating Modes: Profiles and Direct Input

How to use pre-defined profiles or manually input parameters.

Chapter 5: Maintenance

Before You Start Maintenance

Safety precautions and warnings before performing maintenance.

Troubleshooting Common Alarms

Diagnosing and resolving issues based on alarm messages.

Thermode Maintenance and Repair Service

Procedures for thermode cleaning, replacement, and contacting repair service.

Chapter 6: Calibration

Appendix B: Electrical and Data Connections

Emergency Stop and Alarm Reset

Wiring for emergency stop and manual alarm reset functions.