CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908 3-29
MAX. IDLE TEMPERATURE LIMIT
Press the 6 key to bring up the MAX IDLE
TEMPERATURE LIMIT
screen. With this
screen, you set the maximum temperature
that can be entered into a Profile for the
Idle Temperature. A maximum
temperature up to 300C can be entered.
Use the keys to edit
< MAX IDLE TEMPERATURE LIMIT >
MAX AUX TEMPERATURE LIMIT : 300
After edit Page to accept new value
Number Change, Adjust, Graph / Data
DISPLAY AUX TEMP NUMBER
Press the
7 key to toggle between ON and OFF. Selecting ON will display the numeric value for the
Auxiliary thermocouple temperature reading on the
GRAPH and DATA Screens. Select OFF if you do not
wish to display the Auxiliary Temperature.
DISPLAY AUX TEMP LINE
Press the 8 key to toggle between ON and OFF. Selecting ON will display the planned and actual
temperature lines for the Auxiliary thermocouple temperature reading on the GRAPH and DATA Screens.
Select OFF if you do not wish to display the Auxiliary Temperature lines.
SYSTEM SECURITY
From the SETUP MENU screen the 4 key
will bring up the SYSTEM SECURITY
screen.
< SETUP MENU >
1. HARDWARE SETUP
2. COMMUNICATIONS
3. REFLOW SETUP
4. SYSTEM SECURITY
5. COPY PROFILE
6. SET TO DEFAULTS
7. LANGUAGE
8. I/O STATUS
Number Select an item, Graph / Data
This
SYSTEM SECURITY screen allows
you to activate password-only access for
changing the three listed system
functions.
When you select any one of the three
system functions with the keypad, you
will bring up the CHANGE PASSWORD
screen.
<SYSTEM SECURITY >
1. PROFILE LOCK : OFF
2. SYSTEM LOCK : OFF
3. PROFILE TUNING LOCK : OFF
Number Select, Page, Graph / Data