CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908 3-9
Press the 9 key to set the time length of
the x axis of the Graph. The GRAPH
TIME SPAN
can be set from 0 to 600
seconds and can be changed after a
reflow if an expanded or close-up view is
desired of a reflow.
GRAPH TIME SPAN : 030
After edit Page to accept new value
Number Change, Adjust, Graph / Data
Press the
0
key to set the time length of
the
HEAD UP DELAY.
The
HEAD UP
DELAY
starts at the beginning of the
Postheat period and sets the point when
the head will be lifted from the part.
The
HEAD UP DELAY
can be set from 0
to 99.9 seconds. The
HEAD UP DELAY
will only be executed on Profiles with a
POSTHEAT
time greater than 0 seconds.
HEAD UP DELAY : 01.0
After edit Page to accept new value
Number Change, Adjust, Graph / Data
Press the
<
key to set the
IDLE
TEMPERATURE
. The
IDLE
TEMPERATURE
can be set from 25 to
300
°C
. The Control will maintain the
thermode at the
IDLE TEMPERATURE
when both a process is not active and
the
IDLE TEMPERATURE
has been set to
ON
in the Reflow Setup.
IDLE TEMPERATURE : 035
After edit Page to accept new value
Number Change, Adjust, Graph / Data