a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
10
RS3200001 (502992R3)
Rev. 3
8. GRAPHICS PANEL
(Figures 5, 6, 7 and 8)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner wiring.
c. Disconnect wiring from inner components and
carefully remove components from control
hood assembly.
NOTE: Refer to appropriate wiring diagram when
rewiring component parts.
d. Remove three screws holding top cover to
mounting plate. Rotate top cover forward to
release front edge of top cover from top edge
of diffuser, Figure 5, 6, 7 and 8.
e. Carefully remove two control knobs and timer
knob by pulling forward.
f. Remove screws holding end caps to mounting
plate and pry caps off mounting plate.
g. With graphics panel facing forward, rotate
control hood assembly forward to access tabs
holding graphics panel.
h. Bend graphics panel tabs until straight and
pull panel away from control mounting plate.
NOTE: To re-assemble reverse the steps.
9. TIMER
(Figures 5, 6 and 8)
a. Remove the three screws holding the control
assembly to the control hood rear panel,
Figures 5, 6 and 8.
b. Rotate assembly forward to access inner wiring.
c. Disconnect wiring from inner components and
carefully remove components from control
hood assembly.
NOTE: Refer to appropriate wiring diagram when
rewiring component parts.
e. Remove two screws holding timer to mounting
plate.
f. Remove knobs.
10.TEMPERATURE SWITCH
(Not included in electronic control models)
(Refer to Figures 5, 6 and 8)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner
wiring.
c. Disconnect wiring from inner components and
carefully remove components from control
hood assembly.
NOTE: Refer to appropriate wiring diagram when
rewiring component parts.
d. Remove nut holding temperature switch to
control mounting plate.
e. Remove two screws holding temperature
switch bracket (if separate from temperature
switch) to control mounting plate.
f. Using a needle nose pliers, press in on
locking tabs holding temperature switch to
control mounting plate.
g. With locking tabs pressed in, rotate
temperature switch counterclockwise 1/4 turn
and remove switch out rear of control
mounting plate.
11.SIGNAL CONTROL
(Figures 5, 6 and 8)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner
wiring.
d. Disconnect wires to the signal control.
NOTE: Refer to appropriate wiring diagram when
rewiring component parts.
e. Remove signal control knob.
f. Remove two screws holding the signal control
to the control mounting plate.
12.PRINTED CIRCUIT BOARD
(Models with Moisture Sensor Only)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner
wiring.
c. Pull printed circuit board forward to slide off
plastic support pegs.
13.ELECTRONIC CONTROL
(Figure 7)

Table of Contents

Related product manuals