a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
53
RS3200001 (502992R3)
Rev. 3
Figure 51
50.ELECTRICAL CIRCUIT TO IGNITION SYSTEM
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel, Figure 51.
b. Gently lower the access panel to disengage
guide lugs from bottom edge of front panel.
c. Close gas shut-off valve, Figure 48.
d. Remove valve wire harness disconnect block
from the holding and booster coil, Figure 51.
e. Plug dryer power cord into wall receptacle,
start the dryer in a heat setting (refer to the
Operating Instructions supplied with dryer).
f. Set test meter to read AC voltage and apply
meter probes into terminals on the dryer
harness that would correspond to terminals 1
and 2 on the coil, Figure 45. Meter should
register line voltage in all Fabric settings,
except FLUFF which should read zeroVAC.
g. If meter does not read line voltage in step f,
check motor switch, thermostats, fabric
switch, or timer.