a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
68
RS3200001 (502992R3)
Rev. 3
SECTION VII
Service Procedures Unique to the
Electronic Control Model Dryers
a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
Grounding and Wiring Instructions
The dryer must be connected to a grounded
metal, permanent wiring system; or an equipment-
grounding conductor must be run with the circuit
conductors and connected to the equipment-
grounding terminal or lead on the dryer.
The dryer has its own terminal block that must be
connected to a separate branch, 60 Hertz single
phase, AC (alternating current) circuit, fused at 30
Amperes (the circuit must be fused on both sides
of the line). ELECTRICAL SERVICE FOR DRYER
SHOULD BE OF MAXIMUM RATED VOLTAGE
LISTED ON THE NAMEPLATE. DO NOT
CONNECT DRYER TO 110, 115, OR 120 VOLT
CIRCUIT. Heating elements are available for field
installation in dryers which are to be connected to
electrical service of different voltage than that
listed on nameplate, such as 208.
If branch circuit to dryer is 15 feet (4.50 m) or less
in length, use U.L. (Underwriters Laboratories)
listed No. 10 A.W.G. wire (copper wire only), or as
required by local codes. If over 15 feet (4.50 m),
use U.L. (Underwriters Laboratories) listed No. 8
A.W.G. wire (copper wire only), or as required by
local codes. Allow sufficient slack in wiring so
dryer can be moved from its normal location when
necessary.
The power cord (pigtail) connection between wall
receptacle and dryer terminal block is NOT
supplied with dryer. Type of pigtail and gauge of
wire must conform to local codes and with
instructions mentioned in previous paragraph.
The method of wiring the dryer is optional and
subject to local code requirements, Figures 56 &
58.
76.ELECTRICAL SERVICE
(Electric Dryer)
(120/240 Volt, 60 Hertz, 3-Wire Installation)
(120/208 Volt, 60 Hertz, 3-Wire Installation)
NOTE: The wiring diagram is located inside the
control hood.
a WARNING
To reduce the risk of fire, electric
shock or personal injury, all wiring and
grounding MUST conform with the
latest edition of the National Electrical
Code, ANSI/NFPA No. 70, and such
local regulations as might apply. IT IS
THE CUSTOMERS RESPONSIBILITY TO
HAVE THE WIRING AND FUSES
CHECKED BY A QUALIFIED
ELECTRICIAN TO MAKE SURE YOUR
HOME HAS ADEQUATE ELECTRICAL
POWER TO OPERATE THE DRYER.
MODEL
Electronic Control
Assembly
PART NO.
LE9107, LE9207,
LG9109, LG9209,
CE9107, CE9207
500540
LE4807, LE4907,
LG4809, LG4909
501273