a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
23
RS3200001 (502992R3)
Rev. 3
Figure 24
24.BURNER SYSTEM COMPONENTS - Gas
Models
a. Complete Gas Valve Assembly.
(1)While supporting the lower access panel,
remove two screws from bottom edge of
lower access panel, Figure 22.
(2)Gently lower the access panel to
disengage guide lugs from bottom edge of
front panel.
(3)Close gas shut-off valve, disconnect igniter
wires at disconnect blocks, sensor wires
from flame sensor terminals, and wires
from gas valve coils at the quick
disconnect blocks, Figure 24.
(4)Disconnect gas shut-off valve from gas
valve at the union nut, Figure 24.
(5)Remove three screws holding valve and
mounting bracket to base, Figure 24.
(6)Lift gas valve and mounting bracket from
base, Figure 24.
NOTE: The holding and booster coil, and
secondary coil can be replaced individually.
b. Burner Tube, Igniter and Bracket
NOTE: Burner tube and igniter can be removed
without removing gas valve and bracket.