a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
41
RS3200001 (502992R3)
Rev. 3
Figure 45
42.TERMINAL BLOCK OR POWER CORD
a. Terminal Block:
(1)While supporting the lower access panel,
remove two screws from bottom edge of
lower access panel, Figure 22.
(2)Gently lower the access panel to
disengage guide lugs from bottom edge of
front panel.
(3)Remove two screws holding bottom tabs
on front panel to dryer side panels, Figure
22. Swing bottom of front panel away from
dryer far enough to disengage hold-down
clips and guide lugs from cabinet top.
(4)Disconnect wires from door switch,
Figure 21.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
(5)Remove two cabinet hold-down screws,
Figure 35.
(6)Lift cabinet top to a vertical position by
hinging it on the rear hold-down brackets,
Figure 35.
NOTE: When servicing, cabinet top may be
raised and hinged on the rear hold-down
brackets, or supported against wall behind the
dryer.
(7)Remove all wires from terminal block.
(Refer to appropriate wiring diagram when
rewiring terminal block).
(8)Remove screw holding terminal block to
rear bulkhead, Figure 45.