a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
87
RS3200001 (502992R3)
Electronic Control Board Replacement Report
Installation Date:
Model No.
Date Failed:
Serial No.:
Service Company Identification No.:
Both copies of this form must be completed and returned with the control board.
Warranty is void if control board is returned improperly packed or damaged.
1. What was the customer's complaint?
2. Mark the cause of the complaint in the appropriate box below:
Washer Control Failure
Failure in Diagnostic Cycle
Transformer:
Resistance not in 60-100 Ohm range between E1
and E2?
Hot Water Relay K5:
120 Volts not found between P4-1 and E2 in hot
fill?
Cold Water Relay K6:
120 Volts not found between P4-4 and E2 in cold
fill?
Speed Relay K2:
120 Volts not found between E2 and P3-5 in low
speed?
120 Volts not found between E2 and P3-4 in high
speed?
Agitation Relay K3:
120 Volts not found between P3-3 and E2 in
agitation?
120 Volts found between P3-3 and E2 in spin?
Spin Relay K3:
120 Volts not found between P3-1 and E2 during
spin?
120 Volts found between P3-1 and E2 during
agitation?
Ambient temperature is not what control shows in
temperature diagnostics. (Allow washer to return
to room temperature before running diagnostics.)
Dryer Control Failure
Failure in Diagnostic Cycle
Transformer:
Resistance not in 60-100 Ohm range between E1
and E2?
Motor Relay K1:
120 Volts not found between P4-1 and E2.?
Heat Relay K2:
With E3 disconnected, 120 Volts not found
between E3 and E2?
Temperature Regulating Circuit:
“SH” appears in the display window when the
exhaust temperature is less than 175
o
F?
”OP” appears in display window when the dryer
has heated for three minutes.
Ambient temperature is not what control shows in
temperature diagnostics. (Allow dryer to return to
room temperature before running diagnostics.)
Dryer Moisture Sensor Control Failure
Timer Motor Relay K702:
120 Volts not found between “M” and “T”?
Heat Relay K701:
120 Volts not found between “E2” and “E3”?
Temperature Regulating Circuit:
Timer, thermistor, moisture sensor and Temp/
dryness control are functioning and work
correctly.