a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
94
RS3200001 (502992R3)
Rev. 3
YES, IN 3 MINUTES.
YES, IN 5 MINUTES.
Disconnect electric power
to dryer and remove control
hood. Verify that moisture
sensor connector (P1)
on board is secure.
Short out sensor bars in
cylinder and verify zero
Ohms at P1. Clean sensor
bars.
Remove front panel and
verify that connectors to
the moisture sensor are
secure.
Refer to paragraph 96.
NO
Verify that if drying rack is being used,
TIMER is set on TIME DRY.
With dryer cold and with a damp load,
set timer to an automatic cycle, set
Dryness Control for load size and
desired dryness. Press start and verify
that the heat circuit operates.
Does heater turn on or burner fire after
3 seconds?
Does heat turn off prematurely and
stay off?
Disconnect electric power to dryer and
with an Ohm meter, verify that TIMER
switches are correct for the cycle,
Figure 66.
Verify that Dryness/Temp. Control
potentiometer is secure (Figure 68) and
functional (paragraph 94).
Refer to Thermistor chart Figure 63
and, if necessary, disconnect electric
power to dryer and replace.
Check motor switch, limit thermostat,
exhaust, gas valve, or heater.
Check all wiring.
Disconnect electric power to dryer and
replace control.
Is cycle and TEMP/
DRYNESS SETTING
correct for load type?
NO
97. SYMPTOM: HEATER ASSEMBLY OR BURNER SHUTS OFF PREMATURELY. (Load does not dry.)
YES
NO
Disconnect electric power to
dryer and open hood. Verify
that thermistor 3 pin Molex
housing is secure.
Unplug thermistor connector
and measure resistance
across terminals leading
to thermistor.
Infinite Ohms?
Remove front panel and
disconnect the thermistor.
Check resistance across
terminals.
Infinite Ohms?
Disconnect electric power to
dryer and replace thermistor.
YES
YES
Check all wiring.
Disconnect electric
power to dryer and
replace control.
NO

Table of Contents