EasyManua.ls Logo

Amana LE8217*2 - Cylinder Light; Cylinder Light Receptacle

Amana LE8217*2
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
31
RS3200001 (502992R3)
Rev. 3
Figure 36
32.CYLINDER LIGHT (Figure 36)
a. Open loading door and remove screws
holding the lens to the front bulkhead.
b. Turn the bulb counterclockwise and twist out
of light receptacle.
33.CYLINDER LIGHT RECEPTACLE (Figure 36)
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel, Figure 22.
b. Gently lower the access panel to disengage
guide lugs from bottom edge of front panel.
c. Disconnect wires from door switch, Figure 21.
d. Open loading door and remove screws
holding the lens to the front bulkhead,
Figure 36.
e. Disconnect wires from light receptacle
terminals.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
f. Remove two screws holding receptacle to
front bulkhead, Figure 36.
g. Lift light receptacle out of front bulkhead.

Table of Contents

Related product manuals