a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
47
RS3200001 (502992R3)
Rev. 3
Figure 48
47.BURNER FLAME - Gas Models
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel, Figure 22.
b. Gently lower the access panel to disengage
guide lugs from bottom edge of front panel.
c. Set timer at 60minutes.
d. Close the loading door, start the dryer in a
heat setting (refer to Operating Instructions
supplied with the dryer); the dryer will start,
the igniter will glow red and the main burner
will ignite.
e. Allow the dryer to operate for approximately
five minutes, then loosen the air shutter
lockscrew, Figure 48.
f. Turn the air shutter to the left to get a
luminous yellow tipped flame, then turn it back
slowly to the right to obtain a steady blue
flame.
g. After proper flame is obtained, tighten air
shutter lockscrew securely, Figure 48.
h. Reinstall lower front access panel and screws.
a WARNING
To reduce the risk of fire or serious
injury, the access door must be in place
during normal operation.
After the dryer has operated for approximately three
minutes, exhaust air or exhaust pipe should be
warm.

Table of Contents