a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
89
RS3200001 (502992R3)
Figure 65
Moisture Sensor Printed Circuit Board
92.CONTROL REPLACEMENT
See paragraph 93 on handling of electronic
parts, both new and those to be returned.
Disconnect electric power to dryer. Remove
control hood per instructions in paragraph 5-13.
Carefully remove connectors at P1, H3 and E1
through E3 on the control, Figure 65.
Working on one corner of the PC board at a
time, depress the locking tab on the plastic
stand-off with a needle nose pliers and lift that
corner free.
The new control is supplied in an anti-static bag
and protected by anti-static packaging. Carefully
remove control from packaging and bag and
snap into place on the stand-offs. Re-connect
P1, H3, and E1 through E3, Figure 64.
Re-install control hood and supply power to the
dryer. Verify operation per paragraph 5-13.
D155SE3A