a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
91
RS3200001 (502992R3)
Rev. 3
94. TEMP/DRYNESS CONTROL RESISTANCE CHART
POTENTIOMETER (OHMS) AUTOMATIC SETTINGS TIME DRY TEMP °F
0
70
140
210
280
350
420
490
DAMP
DAMP
DAMP
DAMP
DAMP
DAMP
DAMP
DAMP
110
112
114
116
118
120
122
124
560
800
940
1100
1260
1420
1580
1800
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
126
128
130
131
132
133
134
135
1900
2165
2390
2615
2840
3065
3290
3500
EXTRA DRY
EXTRA DRY
EXTRA DRY
EXTRA DRY
EXTRA DRY
EXTRA DRY
EXTRA DRY
EXTRA DRY
136
137
138
139
140
141
142
143
4000
5000
6000
7000
8000
9000
10000
MOST DRY
MOST DRY
MOST DRY
MOST DRY
MOST DRY
MOST DRY
MOST DRY
144
145
146
147
148
149
150
NOTE: Resistance measurements taken with potentiometer disconnected from harness.
Figure 68