a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
49
RS3200001 (502992R3)
SECTION IV
Test Procedures
a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
Figure 49
IMPORTANT: Electrical test procedures in this
service manual are performed by using a Volt-
Ohm meter. Tests can also be performed using a
multi-meter or any other electrical testing
equipment with which the service person is
familiar.
48.DRIVE MOTOR (Figure 49)
a. Remove motor and exhaust assembly,
paragraph 30.
b. Disconnect motor wire harness at motor
disconnect block.
NOTE: Refer to appropriate wiring diagram when
rewiring motor switch.