EasyManua.ls Logo

Amana LE8217*2 - Control will Not Wake up (no LED S Light) after SELECT CYCLE Pad Is Pressed

Amana LE8217*2
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
78
RS3200001 (502992R3)
Rev. 3
*This measurement should be made with a digital Multi-Meter set at 200 Ohm scale for best accuracy.
NO
NO
Go to Blown Fuse or Tripped
Circuit Breaker, paragraph 79.
NO
Plug in.
NO
YES
80.SYMPTOM: CONTROL WILL NOT WAKE UP (No LED's Light) AFTER SELECT CYCLE PAD IS
PRESSED.
YES
Disconnect electric power to
dryer and check for broken,
loose or incorrect wiring from
outlet to control.
YES
Disconnect electric power to
dryer and replace control
Power cord plugged in?
Proper voltage outlet? See
Figure 59.
Check to see that voltage is being
applied to control.
Approximately 120 Volts between
terminals E2 (neutral) and E1 on
heat relay K2?
Disconnect electric power to dryer
and disconnect wires from terminals
E2 and E1. Take resistance reading
through transformer.
*86 Ohms ± 30% between E2 and E1.
Recheck from beginning. If problem
exists, after checking for loose,
broken or incorrect wiring,
disconnect electric power to dryer
and replace control.
YES

Table of Contents

Related product manuals