a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
51
RS3200001 (502992R3)
Rev. 3
Inoperative run winding.
Replace motor.
NO
Inoperative run winding.
Replace motor.
NO
Inoperative run winding.
Replace motor.
NO
YES
YES
START WINDING
RUN WINDING
PROTECTOR
YES
d. Motor Windings. (Refer to SECTION VI.)
a WARNING
Disconnect electric power to dryer before performing any
of the following steps or replacing inoperative motor.
G. 1-2 Ohms between black
wire and orange wire.
H. 1-2 Ohms between yellow
wire and orange wire.
I. Continuity exists between
orange wire and brown
wire.
All motor windings check OK.