EasyManua.ls Logo

Amana LE8217*2 - Page 77

Amana LE8217*2
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
76
RS3200001 (502992R3)
Rev. 3
TIME DISPLAY
ILLUMINATED
LED'S / VFD
MOTOR
RELAY
HEATER
RELAY
SIGNAL
11 ALL ON ON OFF OFF
12 ALL OFF ON ON OFF
33 ALL ON ON ON OFF
44 ALL ON ON ON OFF
55 ALL OFF OFF OFF LOWEST
66 ALL ON OFF OFF MEDIUM
77 ALL OFF OFF OFF LOUDEST
NOTE:
1. This test routine will only light in the LED's (Figure 64) pertaining to the hardware model selected.
2. When the last step in the table is finished, the routine sequence will repeat.
3. Each output is on for two seconds.
DIAGNOSTIC ROUTINE
Figure 62
Figure 61

Table of Contents