Tables
56
AMADRILL+ BAH0040-9 01.19
Mode 7 Code Seed rate reduction when creating a tramline (see
section "Creation of tramlines", Seite 20 and
section "Table for seed rate reduction while creating tramlines", Seite
68)
0
0%
Factory-set value for seed drills
Seed drills D9
Seed drills AD
Seed drills AD-P 3000/3500/4000 Super/Special
15
15%
Factory-set value for pneumatic seed drills,
except seed drills AD-P 3000/3500/4000 Super/Special
0 to 100
0% to 100% = freely adjustable values
Mode 8 Code Pre-metering time when pressing the button
(filling of the metering roller chambers in the metering unit),
see section Pre-metering prior to startup, page 41.
3
Factory-set value (3 seconds)
0 to 5
Adjustable values (from 0 to 5 seconds)
Mode 9 Code
Pre-metering time when starting up (start-up ramp),
see section Start-up ramp, page 41.
10
Factory-set value (10 seconds)
0 to 99
Adjustable values (from 0 to 99 seconds)
Mode 10
Code
Pre-metering speed when starting up,
[in % of the intended km/h] (start-up ramp),
see section Start-up ramp, page 41.
50
Factory-set value (50%)
0 to 100
adjustable values (from 0 to 100%)