Tables
AMADRILL+ BAH0040-9 01.19
57
Mode 11 Code Simulated working speed
(only adjustable on machines with electric full metering unit)
The control terminal works with the simulated working speed if the distance
sensor fails.
The control terminal works with the actual speed again as soon as the
distance sensor sends pulses again, e.g. after a repair.
0
Factory-set working speed
(0 km/h = no simulation)
0 to 30
Simulated working speed (from 0 to 30 km/h)
Mode 12 Code Seed quantity alteration via button actuation
10
Factory-set value (10%)
0 to 100
Adjustable values (from 0 to 100 %)
Mode 13 Code Type and setting of the working position sensor
00
Digital sensor
0.5 to 4.5
Analogue sensor
When lifting the machine, the metering motor switches
off when reaching the height entered.
Enter the height as voltage value (0.5 to 4.5 V).
Smaller value: switch off the metering motor
at low height
Higher value: switch off the metering motor
at greater height