Analog Programming (APG) and Isolated Analog Programming (ISOL)
4-6 M370430-01 Rev B
Table 4-3 APG Pins and Functions J1
Analog Voltage Programming Input
Analog Current Programming Input
Voltage Resistive Programming Input
Current Resistive Programming Input
Voltage Monitor. The scale of this output is set by the APG voltage
input range selected (see Important note below).
Current Monitor. The scale of this output is set by the APG current
input range selected (see Important note below).
External CC/CV. Indicates the state of the operate mode. When in
CV mode, logic high is output and when in CC mode, logic low is
output. Logic is TTL/CMOS compatible.
Current Share. Used to hook up units for current sharing. Output
from master unit. Slave units should be left open.
Current Reference Input. Slave input from current share output on
the master unit.
1. Important: Non-isolated monitor lines are only valid in local control, digital remote and
non-isolated analog programming modes for the respective voltage and current control. If isolated
analog programming is used, the isolated monitor lines should be used as the non-isolated
monitoring lines will not accurately reflect the output state of the power supply.