Remote Operation
5-8 M370430-01 Rev B
RS-485 Communication Cable with Two RJ-45s
Use the top connector of the two 8-pin RJ-45 jacks, as shown in Figure
5-1, to connect to the RS-485 remote interface. Communication cable
with two RJ-45 shielded connectors (see Figure 5-3) connecting the
master unit to the slave unit. The cable length should be 9.84 feet (3 m)
or longer. The pinouts for the RJ-45 plug on the master unit are the same
as described in Table 5-7.
Table 5-7 RJ-45 Plug on Slave Unit
Master unit (J6) Slave unit (J4)
Figure 5-6 RS-485 Communication Cable from Master to Slave Unit
Completing the Setup
To complete the setup:
Configure the XG/XTR to use the 485 remote interface and setup
the terminal that will be used on the connected PC.
See sections entitled “Selecting the Appropriate Communication
Port” on page 5-24 and “Terminal Configuration” on page 5-21 for
more details.