Remote Operation
5-36 M370430-01 Rev B
Figure 5-20 summarizes the Standard Event Status Register.
Figure 5-20 Summary of Standard Event Status Register
Table 5-10 Standard Event Status Register
Set if * OPC command has been received and all
pending operations have been completed.
Not implemented. Always set to 0.
Device Dependent Error
(DDE)
Set if there is a device-specific error.
See “Device-Specific Error List” on page B-5 for a
list possible error codes and descriptions.
Set if a program data element, following a header,
was evaluated by the power supply as outside of its
legal input range, or is otherwise inconsistent with the
power supply's capabilities. Suggests that a valid
program message could not be properly executed due
to some power supply condition.
See “Execution Error List” on page B-4 for a list of
possible error codes and descriptions.
Standard Event
Status Register
(SESR)
Bit
Operation Complete
Not Used
Query Error
Device Dependent Error
Execution Error.
Command Error
Not Used6
Power On
Not Used
Not Used
Error/Event Queue Status
Flag
QUEStionable Status
Summary Bit
Not Used
OPERation Status
Summary Bit