Communications Options
M370430-01 Rev B 6-25
Figure 6-30 Multiple Power Supplies and Two Computers
All devices connect via the HUB. Every device must have a unique IP
address, for example:
• Computer #1: 169.254.117.231
• Computer #2: 169.254.117.232
• Power supply #1: 169.254.117.220
• Power supply #2: 169.254.117.221
• Power supply #3: 169.254.117.222
• Power supply #30: 169.254.117.230.
You must set up every device manually.
To set up for multiple power supplies and two computers:
1. Set up your computer as described in “Setting Up the
Computer” on page 6-5. Repeat the procedure for each
computer hooked up to the system.
2. Install the DeviceInstaller software on the PC you wish to use
to configure the XG/XTR unit (s) with. See the instructions
for “Software Installations” on page 6-8.
3. Configure each XG/XTR unit with an ENET option. See the
instructions for “Configuring the Device Using
DeviceInstaller” on page 6-10.
4. Create terminal connections for each of the XG/XTR unit (s)
with the ENET option that were configured in step 3. See the
instructions for “Terminal Configuration” on page 6-16.
5. If more than one computer is going to be used, copy the
filename.ht files saved in step 3 to a disk and copy them over
Local Computer #1 Local Computer #2
ENET
ENET
ENET
Power Supply #1
Power Supply #30
Power Supply #2
HUB