Remote Operation
M370430-01 Rev B 5-71
can only be controlled using a SCPI command as there is no front panel
equivalent. The default value of the interlock is set to Disabled.
Important: The Interlock alarm cannot be masked or latched through the
alarm protection mechanisms. It can only be enabled or disabled using the
following command.
Commands:
[:]SENSe[<channel>]:PROTection:INTerlock[:STATe]
{?|ON|OFF}
Where
ON enables the use of interlock protection.
OFF disables the use of interlock protection.