Deceleration Distance
Arcode does not need any additional settings to determine deceleration distance because of its direct approach feature.
To make comfort settings, “Travel curve
settings” must be selected which is located under
Driver Settings”. Choose “comfort setting
parameter and press Enter button.
Default settings of “comfort settings” as
comfort:3/Performance:3 is set. For that
situation both comfort and performance is set as
nominal.
If you want the elevator stops quickly you
should decrease comfort value. The performance
will increase when comfort is decreased.
If you want more comfort you should increase
comfort parameter. This time, performance will
decrease.
Figure-20: Comfort level