Arkel ARCODE - Appendix-3: Permanent Error Handling; Clearing Permanent Errors

Arkel ARCODE
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Arkel Elektrik Elektronik San. ve Tic. A.Ş. www.arkel.com.tr
ARKEL 61 ARCODE
TÜRKÇE
ENGLISH
EPro:
in the process of reading from Eprom or writing to Eprom now
0.00:
SEV key is activated. The elevator is stopping, speed value is 0.00 m/s
LuL :
SEV key is activated. The elevator is moving with brake releasing. The car is at the door-zone and speed
is lower than 0.3 m/s.
StoP:
SEV key is activated. The elevator is moving with brake releasing. The speed is greater than 0.3 m/s.
UpEx(x=9..0)
Enca software is being updated. "x" number shows the remaining time of update. It counts from 9 to 0.
When it reaches 0, update process is ended.
u36:
the car runs away from the floor which detects fire in U36 function mode.
Parc:
It is going to park floor.
noSr:
The elevator is in “Out of Service” mode with “OOS” input.
In order to clear the permanent error, the following 2 steps should be performed.
On AREM,
1) Tools System Tools Clear Permanent Error
2) Tools System Tools Reset System
Appendix-2
Appendix-3