2
WARNINGS CONCERNING APPLIANCES CONTAINING R32 REFRIGERANT
• This device contains R32 refrigerant, a class A2L refrigerant, which is considered to
be potenally ammable.
• Do not discharge R32 uid into the atmosphere. This is a uorinated greenhouse
gas, covered by the Kyoto Protocol, with a Global Warming Potenal (GWP) = 675
(European regulaon EU 517/2014).
• In order to comply with the applicable standards and regulaons in terms of the
environment and installaon, in parcular Decree No. 2015-1790 and/or European
regulaon EU 517/2014, a leak test must be performed on the cooling circuit when
the appliance is rst started and at least once a year. This operaon must be carried
out by a specialist cered to test cooling appliances.
• Install the unit outdoors. Do not install the unit indoors or in an enclosed, non-
venlated area.
WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES
• The power supply to the appliance must be protected by a dedicated 30 mA Residual
Current Device (RCD), complying with the standards and regulaons in force in the
country in which it is installed.
• The equipment not include electrical switch for disconnecon; include a
disconnecon supply device in the xing wiring at least OVC III, in accordance
applicable naonal laws.
• Do not use any extension lead when connecng the appliance; connect the
appliance directly to a suitable power supply.
• Before carrying out any operaons, check that:
- The required input voltage indicated on the appliance informaon plate
corresponds to the mains voltage;
- The mains supply is compable with the appliance's electricity needs and is
correctly grounded.
• In the event of abnormal operaon or the release of odours from the appliance,
turn it o immediately, unplug it from its power supply and contact a professional.
• Before servicing or performing maintenance on the appliance, check that it is
powered o and completely disconnected from the power supply. Moreover,
check that the heang priority (where applicable) is deacvated and that any
other device or accessory connected to the appliance is also disconnected from
the power supply.
• Do not disconnect and reconnect the appliance to the power supply when in
operaon.
• Do not pull on the power cord to disconnect it from the power supply.
• If the power cord is damaged, it must be replaced by the manufacturer, an
authorised representave or a repair facility only.
• Do not perform maintenance or servicing operaons on the appliance with wet
hands or if the appliance is wet.
• Before connecng the appliance to the power supply, check that the connecon
unit or socket to which the appliance will be connected is in good condion and
shows no signs of damage or rust.
• In stormy weather, disconnect the appliance from the power supply to prevent it
from suering lightning damage.
• Do not immerse the appliance in water or mud.
• Deacvang, eliminang or by-passing any of the safety mechanisms integrated
into the appliance shall automacally void the warranty, in addion to the use of
spare parts manufactured by unauthorised third-party manufacturers.
• Do not spray inseccide or any other chemical (inammable or non-inammable)
in the direcon of the appliance, as this may damage the body and cause a re.
• Do not touch the fan or moving parts and do not place objects or your ngers in the
vicinity of the moving parts when the appliance is in operaon. Moving parts can
cause serious injury or even death.