29
Remote Talkback
The Master Meters
4 POWER RAIL INDICATORS Show the current status of
the power rails of the console. If they are all lit up then
all is well. If any of the power rail lights aren’t on but
the PSU is, then it indicates that there is an issue and
we would recommend contacting us at: support@
audient.com
5 HEADPHONE OUTPUT. The ASP8024-HE includes
a reference grade Headphone Amplifier which is
accessed by routing the audio to the ALT 3 outputs
in the Monitor Control Section of the console. The
headphone jack is a standard 6.35mm TRS jack.
6 GAIN REDUCTION METER. The Gain Reduction Meter
shows you the amount of compression that is being
applied.
1 SUB GROUP METERS. The Sub Group Meters
show you the post fader signal level of the Sub
Groups including an OVER indicator to alert you
should you reach the headroom limit of the Sub
Groups.
2 TALKBACK MIC CONNECTOR. Use this to connect
any standard microphone for talkback use. The
connector has +48V Phantom Power for use with
condenser mics. Phantom Power can be switched
o by removing the jumper at LK1 on the Master
Meter circuit board.
3 MAIN METERS. show you the level of the mix
outputs after the Master Fader. This includes
an OVER indicator to alert you if you reach the
headroom limit of the Mix Outputs.
5 6
43
2
1

Related product manuals