Survivable Branch Appliance
AudioCodes Enhanced Media Gateway 62 Document #: LTRT-18206
Figure 4-6: Admin Page
5. On the left pane, click ini Parameters.
6. In the 'Parameter Name' field, enter the parameter FakeRetryAfter. When the Gateway
receives 503 without Retry-After response-header, it will behave as if the 503 response
includes a Retry-After response-header with the period specified by the parameter
FakeRetryAfter.
7. In the 'Enter Value' field, enter “60”.
8. Click Apply New Value.
9. Save the changes to flash memory, by clicking the Burn button on the toolbar.