Table 7:
Weights for output drive type
[kg]Flange sizeType designation
1.1F07A 07.2
1.3F10
2.8F10A 10.2
6.8F14A 14.2
11.7F16A 16.2
Table 8:
Weights for output drive type
[kg]Flange sizeType designation
5.2F10AF 07.2
5.2F10AF 07.6
5.5F10AF 10.2
13.7F14AF 14.2
23F16AF 16.2
3.2. Storage
Danger of corrosion due to inappropriate storage!
Store in a well-ventilated, dry room.
Protect against floor dampness by storage on a shelf or on a wooden pallet.
Cover to protect against dust and dirt.
Apply suitable corrosion protection agent to uncoated surfaces.
Risk of damage due to excessively low temperatures!
Actuator controls may only be stored permanently down to 30 °C.
On request, actuators controls may be transported in specific cases and for
short duration at temperatures down to 60 °C.
Long-term storage
For long-term storage (more than 6 months), observe the following points:
1. Prior to storage:
Protect uncoated surfaces, in particular the output drive parts and mounting
surface, with long-term corrosion protection agent.
2. At an interval of approx. 6 months:
Check for corrosion. If first signs of corrosion show, apply new corrosion protec-
tion.
15
SAEx 07.2 SAEx 16.2 / SAREx 07.2 SAREx 16.2 Control unit: electronic (MWG)
ACExC 01.2 Non-Intrusive Profinet Transport and storage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SAEx Series and is the answer not in the manual?

AUMA SAEx Series Specifications

General IconGeneral
Explosion protectionATEX, IECEx
Ingress protectionIP66 / IP68
Communication interfacesModbus, Foundation Fieldbus
DisplayLCD
Control Signal4-20 mA
Type of controllerElectric actuator controller

Related product manuals