Axess Pro Series 3000 Owner Installation Instructions
Technical Specifications Single Phase Three Phase
Power supply 230V - 240Va.c. 50Hz Three Phase 415 Volts AC
Motor type Single Phase 240 Volts (Delta Connection) Three Phase 415 Volts AC (star connection)
Model
Motor Power
Maximum shutter opening
AX3105
0.5HP
18m
2
AX3110
1.0HP
36m
2
AX3305
0.5HP
18m
2
AX3310
1.0HP
36m
2
AX3315
1.5HP
50m
2
Opener Limits Travel 30.5 turns of output shaft 30.5 turns of output shaft
Duty Cycle 60% 60%
Receiver type UHF Multi-frequency FM Receiver UHF Multi-frequency FM Receiver
Receiver code storage capacity 511 X 4 button Transmitter Codes 511 X 4 button Transmitter Codes
Receiver Sensitivity – 103 dB – 103 dB
Transmitter frequency UHF Multi-frequency FM Transmitter UHF Multi-frequency FM Transmitter
Coding type Code hopping Code hopping
Number of code combinations Over 100 billion random codes Over 100 billion random codes
Code generation Non-linear encryption algorithm Non-linear encryption algorithm
Courtesy light Common Collector Transistor output Common Collector Transistor output
Mains fuse FLQ10 - 500 VAC time delayed fuse x 3
Controller fuse 10A slow blow TDC11 - 250 milliamp 1000 VAC slow blow fuse
Transmitter Battery CR - 2032 (3 Volts) CR - 2032 (3 Volts)
Real Time Clock Battery CR -1220 (1.5 Volts) CR -1220 (1.5 Volts)
NOTE:
a. If the Safety Beams are not installed then the controller will automatically go into “Safety Close“ mode. A limited
number of features are available in this mode, please refer to menu 6.1 in Section 16.1.