Chapter 6: Accessories
Page 6–11Stellar
®
SR55 Series Soft Starter User Manual – 1st Ed, Rev F – 09/18/2019
Cooling fan replaCemenT meThod seleCTion floWCharT
Use the flowchart below in order to determine which fan replacement method and
instructions to use.
Note for SR55-156 and SR55-180 Soft Starters Cooling Fan Replacement
For SR55-156 and SR55-180 soft starters, the fans and internal fan supply voltage could
be either 12VDC or 24VDC, depending upon when the soft starter was manufactured. The
replacement fan kit (SR55-FAN-6) includes a 12VDC fan and a resistor for use in the 24VDC
starters as described below.
For early-model SR55-156 and SR55-180 soft starters, one of the original fans must be removed
to observe the voltage rating label. SR55-156 and SR55-180 soft starters with original equipment
24VDC fans will require two SR55-FAN-6 fans kits, and both fans will need to be replaced.
Is serial #
> A32794?
Model is
SR55-156 or
SR55-180
Check fan
voltage
Fan =
12V
Fan =
24V
End
Use
method #1
Use
method #1
Use
method #2
Yes
Yes
Yes
No
No
Yes
No
End
End
Start
Model is
SR55-414 or
SR55-477
Yes
No
End
Use
method #3
End
Use
method #1
SR55 Soft Starter Fan Replacement Method Selection