7 User Screen
138 © Copyright Reserved Autonics Co., Ltd.
(3) Screen position
Start position of
screen
(left-upper
point)
(0, 0) (0, 0) to (779, 459)
End position of
screen
(right-lower
point)
(799, 479) (19, 19) to (799, 479)
Position by
screen type
Base screen size is not
changeable and has fixed
coordinate value.
If window screen is over maximum size, right-
lower point moves automatically to the end
point of screen. Therefore, it may different
between user-defined position and window
screen position.
(4) Screen number and the number of screen
Screen number Enable to designate from 1 to 500 range
The number of
designable screen
500
The number of
downloadable screen
500
※
1
3
※
2
※1. If designed base screen capacity is over user data area, data transmittion does not
operates normally. Please check designed data capacity and download it again.
※2. Designed window screen is for user-defined key pad. In this case, maximum number of
downlodable screen to LP is 3.
7.2 Screen display object
(1) Available display object by screen type
Available display
object
Line, rectangle, circle, text,
bitmap, numeral display, ASCII
display, numeral input
※
1
, ASCII
input
※
1
, clock, comment list,
alarm history
※
1
, alarm list
※
1
,
part display, lamp display,
line graph, trend graph,
bar graph, statistic graph,
panel meter, touch key
Line, rectangle, circle, text,
bitmap, numeral display, ASCII
display, clock, comment list
part display, lamp display,
line graph, trend graph,
bar graph, statistic graph,
panel meter, touch key
※1. These are displayed only on base screen.