Connecting & Checking Two-Wire Telephones
All two-wire devices (POTS) should be tested according to the manufacturer's instructions before
connection to the IP Office system. Connect the two-wire device and make a test call.
Power Fail Telephones and Sockets
All power fail sockets (on IP400 Analog Trunk 16 modules only – see IP400 Analog Trunk 16) must be
tested.
To test a power fail socket
:
1. Locate the socket and check that it is clearly labeled as a power fail socket.
2. Connect a telephone to the socket.
3. With power to the IP Office system switched on, make a test call.
4. Switch the power to the IP Office system off and again make a test call.
5. Switch the power to the IP Office system back on again.
6. Repeat the test for any other power fail sockets.
Note
Where E911 statuary requirements for discrete location identification of a power fail
phone are required on the transmitted CLI, ensure that the relevant installation
programming is completed.