Chapter 1: Introduction
10 Installing and Configuring the Avaya S8400 Server January 2008
● Verify that the rail kit that is required to support the UPS is installed on the rack or available
to install. For how to install the rails, see the documentation that comes with the rail kit.
● Verify that the equipment racks are grounded per local code. See Job Aid: Approved
Grounds (555-245-772).
● Verify that the customer-provided AC power to the rack is from a nonswitched outlet.
Equipment specifications
The control network components of the S8400 Server consist of a G650 Media Gateway with a
TN8400AP circuit pack that is installed in slot 2, a TN8412AP (SIPI) that is installed in slot1, and
one UPS. The physical specifications for the S8400 control network are shown in Table 1
.
Table 2
shows the specifications of the TN8400AP circuit pack.
Note:
Note: Values of some parameters may change with future versions of the TN8400.
Table 1: S8400 control network components specifications
Component Dimensions
English
(height x width x depth
in inches
)
Dimensions
Metric
(height x width x depth
in centimeters
)
Height
(u)
Weight
(lb/kg)
G650 Media Gateway 14 x 17.5 x 22 35.5 x 44 x 56 8 39/18
UPS:
700 VA
1500 VA
3.5 x 17 x 19
3.5 x 17 x 24
9 x 43 x 48
9 x 43 x 61
2
2
34/15
50/23
Table 2: TN8400AP specifications
Feature Specifications
Microprocessor Intel Celeron M (600 MHz)
Memory 512 MB RAM
Storage IDE SSD, 2 GB
IDE hard drive