Adjusting Needle Spacing
1. Open the front door.
2. Turn the Knob and adjust the space between the two needles. When you adjust the needle spacing,
please make sure that the Ejector Rods move according to the needles, if the Ejector Rods do not
move then there might be some friction with the Ejector Rod guide at the top. Please use your finger
to help it move if necessary.
3. The adjustable range of needle spacing is 6~12 mm, you may read the data from the scale at the plate.
needle spacing
Ejector Rod Guide