Model E1070 Indicator Service Manual
CAL submenu for
SensorComm scales
Figure 15
SensorComm cornering menu
1. Access the Service menu. . .
CAL is displayed.
2. Press the PRINT key. . .
CORNER is displayed. Use this item to corner the SensorComm
system.
3. Press the PRINT key. . .
DLOAD is displayed. This stands for deadload.
4. Press the PRINT key. . .
Numeric entry screen is displayed.
5. Key in the size of your cornering (test) weight. Press the ENTER key to
enter this value and to record the deadload weight. . .
BUSY is briefly displayed and then DLOAD is displayed.
6. Press the UNITS key. . .
1 is displayed. This stands for sensor #1.
7. Press the PRINT key. . .
mV/V is displayed for sensor#1.
8. Place the cornering weight over sensor #1. Wait for the scale to stabilize
then press the ENTER key. . .
BUSY is briefly displayed and then 1 is displayed.
If your system is set up for a SensorComm j-box, the shaded portion of the
calibration menu is the first item. See Figure 15. Follow these steps to
corner the system and then continue on with the calibration procedures
outlined in CAL submenu for analog scales.
CORNER
(SensorComm Cornering)